utility room lock

RELATED FAQS

Question
Answer
The E201 message can be ignored and all normal SUS and lock functions will be maintained.  Click "OK " and continue. Update the Schlage Utility Software (SUS) to version 4.6.0 or highe...
-         With the CIP NOT inserted and the Schlage Utility Software (SUS) running o   Enter the Master Programming PIN or Present Loc...
Follow step 6 of the 18-R instructions to convert trim function to Night Latch(L-NL).
The 81 service manual can be found here.
The Schlage L-Series uses a clover leaf cam with the exception of the L9060 outside cylinder which uses a straight cam. The cam part number will depend on the type of mortise cylinder, keyway (for ...
The L9466 Store/Utility Room lock can provide this functionality. Operation: Latchbolt retracted by knob/lever either side. Deadbolt thrown or retracted by key from either side. When the deadbolt ...
Storeroom/utility room lock - Latchbolt is operated by knob/lever from either side. Deadbolt is operated by key from either side. - Caution: Double cylinder locks on residences–or on any door in an...
To convert the Von Duprin 9975NL(Night Latch or Storeroom) to 9975L (Classroom) exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL ...
To convert the Von Duprin 9975L to 9975NL exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL screw on 7500 mortise lock counter clo...
Night Latch (NL)= key retracts the latch momentarily to allow entry. When key is removed, the latch will extend and locks the door (momentary unlock). Class Room (Lock/ Unlock)= key unlocks...
Overhead Concealed door closers are used to provide a more aesthetic look to the opening.  Concealed in either the frame or the door Offer the ability to be adjusted to maintain control o...
The coin cell Nuisance Delay on CO200 and CO250 can be temporarily disabled using the Schlage Utility Software.
Once disabled via the SUS application, the CO lock will no longer delay the access for valid credentials.
If your CO lock began indicating a low coin cell (Nuisance Delay) after a door file has been downloaded, the coin cell is low and should be replaced. (CR2032)The coin cell Nuisance Delay will be "A...
The coin cell Nuisance Delay settings in the SUS application is not available until such time that a Door file is successfully downloaded to the lockset.
The coin cell is ignored when the lock sets are used with Manual Programming ONLY or while in Construction mode.
Make sure the lock AA batteries are good. 4.8 VDC or higher.
When in its “Active state”, the mechanical key switch can prevent USB connection. Make sure the lock key cylinder and tailpiece are properly installed.
Make sure the mechanical triangles on the back of the outside escutcheon are aligned properly.  See the installation instructions at www.schlage.com/support Schlage Technical Support.&nbs...
If the Schlage Utility Software pops up a "E201 error", just ignore it, and tap "Device Options" or update your firmware. See 78451  
Make sure the HHD/SUS is set to USB communication by checking the small icon right of the "No Device Connected" message.  The symbol should be a USB symbol when working with USB enable product...
Apartment Corridor Lock function is defined as a lock where the latch bolt operated by lever from either side, except when outside lever is made inoperative by a stop or mechanical means other than...
The use of Panic Hardware and/or Fire Exit Hardware is required by the International Building Code (IBC) and NFPA 101 – The Life Safety Code, depending on which code and which edition of the code i...
When you want to periodically disable and block access to a certain room in a building or an entrance door, that’s when you would need to use a Lockout Cylinder. See full document.
 See the attached Technical Note for instructions on saving a "Device Template" FROM a device or loading TO a device, Device Template Tech NoteOn the SUS/HHD go to the LOCK Properties tab, and sele...
MultiPoint locks are three-point locking systems that secure the door at three points – top, bottom, and traditional center latch location. Operating just like traditional locks, MultiPoint locks a...
Schlage offers a High, Medium, and Low risk HSLR ligature Resistant trim offering for the L9000 and ND locks, Data Sheet.Schlage offers a Low to Medium Risk SL1/SK1 ligature resistant trim for...
High Risk Areas*Patient bedroomIn-suite bathroomIn-suite closetTime-out roomPatient difficult to manage; or risk of solitary and/or unsupervised areas.Medium risk areas*Living roomDining roomGroup ...
The ND85/AL85/A85 hotel lock is only available in a conventional Key-in-Lever cylinder.  Interchangeable core and Primus are not available with this function. 
A Primus Hotel cylinder (as well as an IC hotel cylinder) is not possible because there isn't enough room inside the cylinder for all of the required components. 
The SUS (Schlage Utility Software) will not run or work on the older HP IPAQ PDAs. The older HP IPAQ PDAs run CEUplink to interface and program legacy locks. The SUS (Schlage Utility Software) will...
You can contact Allegion Customer Service (Sales Support) or Technical Support (Product Support) by phone or by email. To contact by phone: call 877.67...
NOTE: You can also reach your local sales office by dialing 877-671-7011 and selecting option #3 from the main menu. You will be directed to your sales office based on the area code ...
This change was implemented in firmware package CO.A.6 (or later) to help the customer in the communication and coupling process between the CO200 (CO250) and the hand held device (HHD). ...
The green LED is to be lit up until the spindle (Triangles and Key Switch) are aligned properly; providing a visual indication of the problem.  
If the mechanical alignment of the triangles on the back of the outside escutcheon are not aligned, the CO200 or CO250 will not connect with the SUS/HHD and will appear to be unresponsive...
In firmware CO.A.6 (or later) the Schlage button on the CO200 (CO250) will turn green anytime that the spindle triangles on the front escutcheon are out of alignment or the mechanical key switch is...
When unlocking the CO200 door by mechanical key override, the green led will be continuously ON until the key is released. This will occur after firmware CO.A.6 (or later) has been installed int...
Once a user changes the SUS coupling password , the previous SUS coupling password is also saved by the SUS program; this allows the user to update multiple locks with a new Coupling Password witho...
The Coupling Password update is automatic; whenever the Schlage Utility Software, with a new Coupling Password connects with a device, the Schlage Utility Software will automatically update its old...
The internal process to couple a device with new SUS password is described as follows: the SUS first tries to couple with the current password.  If that fails, the SUS tries to couple with the prev...
To verify that the device/lock is coupled; click on the SUS device options-> Couple HHD to device , a message will pop up confirming that the device is already coupled.  
After updating the SUS coupling password, subsequent HHD’s will need the new coupling password entered before they can update any information in the lock, once the HHD has the correct coupling pass...
Customers will need to use the Schlage Utility Software (SUS) on the HHD lock programming device to set the desired magnetic track to be read for access control, if not using default Track 2&n...
Update your lockset using ADFwPkg 2.19.0 or higher.  This new firmware update resolves this programming error problem (E701) and the error will no longer be presented.
Falcon replaced its deadbolt offering in 2008 with the D100 and D200 series.  The D800 Grade 2 deadbolt was replaced by the D200 and the D400 Grade 1 deadbolt was replaced by the D100.   The new bo...
  Part compatibility (Old vs new): With the exception of the cylinder, most of the parts are neither backward nor forward compatible.  This includes the deadbolt. The cylinder mechanism for al...
The AL and ND locks are not available in any stainless steel finishes.  The only option is either the 626 satin chrome or 625 bright chrome.
Microsoft Windows 8, 7, Vista, and XP: Home, Basic, and Starter versions are not compatible with Schlage Express. What versions of Microsoft Windows are compatible with Schlage Express v...