verticle rod not required on bottom

RELATED FAQS

Question
Answer
Installation should be 6" from bottom of the door. See attached templates as reference.  T-5494 for HM Doors W-5494 for Wood Doors
Following parts are required to add the bottom rod and latch to the 98/9927-LBR/LBR-F device.  Bottom Rod: 050515 for 9827 and 050514 for 9927 (specify finish)  Bottom Latc...
One of the following items may cause the EL1690 device to retract then release: Incorrect power supply - Verify you have the PS873-2/4TD or PS914-2RS/4RL power supply. Problems with wire gauge...
The following items may cause the exit devices top latch from being held in the retracted position. 1. The top or bottom rods are out of adjustment. 2. The top latch hold back...
Following exit devices 2227/F, 33/3527A/F, 33/3547A/48A/F, 98/9927/F and 98/9947/48/F have similar rod adjustment procedures. All top latches control the bottom latch assemblies. When do...
One of the following items may cause the EL1490 device to retract then release: Incorrect power supply - Verify you have the PS873-2/4TD or PS914-2RS/4RL power supply. Problems with wire gauge...
The 6111 electric strike can be used only on non rated openings less bottom rod with pullman top latch (use ES prefix when ordering device). Device back set will change to match the centerline of t...
Not for use in fire rated openings.
Von Duprin now offers an 8827 LBR panic device as of October 7, 2019. This device uses the top rod assembly and soffit latch setup of the fire rated 8827-F device, but has dogging, a UL Panic Har...
Von Duprin offers a PL8827 LBR device with a pullman style top latch and Less Bottom Rod for use with electric strikes, but is not UL labeled nor ANSI/BHMA certified.
This is available. If this is a fire rated opening you must use the Auxiliary Fire Latch Kit to maintain your Fire Rating.  If not fire rated simply omit the bottom rod but be aware that your...