von duprin bottom rod length

RELATED FAQS

Question
Answer
The top and bottom rod itself is 35" long standard.
Von Duprin will not supply the 8827-F less the bottom rod because the device has never been UL tested less bottom rod.
The 6111 electric strike can be used only on non rated openings less bottom rod with pullman top latch (use ES prefix when ordering device). Device back set will change to match the centerline of t...
Not for use in fire rated openings.
To add the bottom rod and latches on 8827LBR it requires Bottom Rod Kit part #050455-XX 8827 Rod Guide Kit part #50482-XX 8827 LR Bottom Latch Kit W/Cover part #050467-XX 304L Bottom Strike
Following parts are required to add the bottom rod and latch to the 98/9927-LBR/LBR-F device.  Bottom Rod: 050515 for 9827 and 050514 for 9927 (specify finish)  Bottom Latc...
The following items may cause the exit devices top latch from being held in the retracted position. 1. The top or bottom rods are out of adjustment. 2. The top latch hold back...
Following exit devices 2227/F, 33/3527A/F, 33/3547A/48A/F, 98/9927/F and 98/9947/48/F have similar rod adjustment procedures. All top latches control the bottom latch assemblies. When do...
The Von Duprin 2227 or 2227-F  exit device is available less bottom rod.  Specify 2227-LBR or 2227F-LBR for fire.
This is available. If this is a fire rated opening you must use the Auxiliary Fire Latch Kit to maintain your Fire Rating.  If not fire rated simply omit the bottom rod but be aware that your...
The internal rods and latches for the 25-C carried over from the older 18-C device so they can be used interchangeably.
One of the following items may cause the EL1690 device to retract then release: Incorrect power supply - Verify you have the PS873-2/4TD or PS914-2RS/4RL power supply. Problems with wire gauge...
Installation should be 6" from bottom of the door. See attached templates as reference.  T-5494 for HM Doors W-5494 for Wood Doors
The extension rod could be used either on the top or bottom rods.