von duprin electric strike

RELATED FAQS

Question
Answer
Von Duprin offers no such strike.  The reason being that the deadbolt would bounce off the strike’s keeper and prevent the door from securing.
No, the Von Duprin 5654 aluminum mullion will NOT accept an electric strike.  Most electric strikes require 1 1/4" to 1 1/2" of frame "face" to mount flush to the mullion.  The 5654 mulli...
No, due to the gate and backbox not being able to be sealed to keep water out of the electric strike a weather proof version is not available.
If the solenoid of the 6000 series electric strike is powered continuously with proper voltage at room temperature, the solenoid can reach 200-220 degree Fahrenheit.
To use the 5547 with an electric strike you would need the ES top rod & latch part number 050656-00 and remove the bottom rod and latch. The 6213 electric strike is recommended with 5547LBR, non fi...
There is not enough room to install two 6111 electric strikes back to back in 4854 mullion.
Von Duprin doesn't offer any electric strike to fit into 1 1/2" aluminum/metal faced frame.  Minimum requirement to install 6211/6211AL is 1 15/32" mortise depth.
The 5100 strike details are listed below: Only operates with 12VDC or 24VDC power supply. Will not operate with AC transformer. 12 or 24VAC can be converted to 12/24VDC using Von Duprin SO12 o...
The 5100 electric strikes are for use with cylindrical locks only.  Instead use the following:6211 electric strike is used with mortise lock without deadbolt on a new single door, hollow ...
We do not offer mounting tabs for 6000 series electric strikes.  However, the mounting tabs found in PKGMTG.1004 for the 5100 series mounting package could be used.  The frame or d...
To convert the Von Duprin 6000 series electric strikes from FS to FSE  or from FSE to FS follow these steps: Remove the electric strike face plate. Remove the strike box cover pl...
Part numbers: FS slider, part # 970387 (6211WF/6212WF/6221/6223 only) FS slider, part # 970388 (Except 6211WF/6212WF/6221/6223) FSE slider, part # 970388 (6211WF/6212WF/6221/6223 only) FSE sl...
The Von Duprin 6000 series electric strike can be converted by ordering the appropriate kits below.  Kits include the solenoid, plunger, spring, and washer. 6000 Series solenoid Kit 12VDC -...
Option boards are not required with PS900 series power supplies when using electric strikes. See the list of options below. The PS902 would power up to 5 electric strikes at 24VDC or&n...
Von Duprin 6223 electric strike is the most common closed back strike or the 6221 for open back strike on inactive leaf that can be used with Schlage L9000 or Von Duprin 7500 mortise lock.
The operating temperature for 6000 series electric strike is -20 to 120 degrees Fahrenheit.
The power supply output in the 7900 series control box is a 12VDC output, rated at (1/4A) 0.250A. It cannot be used to power a strike or maglock. You need to have a separate power supply for the st...
***The 6210 electric strike was designed to replace mechanical strikes in existing openings when access control is desired.*** Note: The Best 40H series lock is not listed on the 6210 electric s...
Electrical hinges or a power transfer units are the most commonly used practices to run electric power to locks and/or strikes. Electric Hinges: Most electric hinges will fit into...
 The 10-042 is an electric strike used for cylindrical and tubular latch sets.  VOLTAGE  24 VAC  12 VDC  AMPERAGE  0.74A 0.33A   FREQUENCY  60 HZ ...
The 4600 Series operator has both a 12VDC and 24VDC output rated at 1A (combined load) to power strikes, maglocks, and other devices, but an EL device "always" has to have a separate PS914-2RS Seri...
You can replace the 6210 spring and lip, part number 050940-00.
Schlage offers the 10-042 Electric strike, 1 1/4" x 4 7/8", 606 and 626 finish only. Related solution: What are the current and voltage requirements of the 10-042 strike?
The 8200 Series operator CANNOT power a strike, maglock, or EL device. A separate power supply is ALWAYS required. There is an onboard relay to control a strike, maglock, or EL device.
The Locknetics 9100 series electric strikes are replaced with Von Duprin 6211 and 6210 electric strikes.   The 6211 is used if the frame is being replaced. The 6210 is for ...
The Falcon 25R rim device can be used with 6111 electric strike on single or double doors. Additional Information: The Von Duprin 4854/9854 mullion is required when using 25R...
For the backset see the Falcon (F)25-R template; T-1201 for Metal Door, W-1201 for Wood Door. For Single Doors, the distance from the surface of the raised stop to the Centerline of the device is...
The 4630/4630 operator has a 12 VDC and 24 VDC output that can power an electric strike or maglock. The wiring diagrams are shown on page 14 of the installation instructions (attached). 4600 Insta...
Follow the steps below to troubleshoot the problem. Measure the voltage at the electric strike. If the strike is FSE and not locking there should be no voltage at the strike and if it is FS there ...
Electric strikes are not water proof an not recommended for exterior application especially gates.
The Von Duprin 6300 surface mounted electric strike is only available as Fail-Secure.
The 6216 electric strike was designed only for use with only the Folger Adams 310-3-1 mortise lock with deadbolt. The dead bolt must be retracted manually for the the strike to operate.
The 6211 would be the most common electric strike to be used with cylindrical locks on a single door application.  Check the template to confirm compatibility with specific cylindrical lock model n...
The Von Duprin 6000 series electric strike has a 12 or 24VDC solenoid with plunger, spring and impact washer as shown 6000 solenoid Make sure the solenoid spring and impact washer are not missin...
An electric strike or maglock (24 volt only) can be wired to a Senior Swing 2800/9500 series operator using the P10 Lock Interface cable. To power the 24VDC electric strike or maglock off a LCN Se...
Electronic latching device that replaces a regular lock strike in a doorframe
This application is not recommended as elelctric strikes have never been tested with XP98/99 exit device because it would defeat the XP device holding force purpose.   The holding force f...
 Von Duprin surface mounted 6300 electric strike paper template and installation instruction are provided with the electric strike. See attached 6300 Template & I...
Order the 4854 mullion 'BLANK' x size x finish
The wires on 6000 series electric strike solenoid are non polarized.
Aluminum mullions 5654 or 5754 are not designed to accept any electric strike including 6300 surface mounted electric strike.
The strike will always be DC.  By using a SO24 or SO12(rectifiers) you will be able to convert the AC waveform from a transformer to a DC waveform that will be acceptable by the 6000 series strikes.
The Von Duprin 6111 electric strike would work with DOM 1790 device on medium style doors Centerline of the 1790 device mounting screws are located 1 11/16" from face of stop. See d...
The Von Duprin 6300 surface mounted electric strike is compatible with 55 rim device.
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullion
The 6111 electric strike can be used only on non rated openings less bottom rod with pullman top latch (use ES prefix when ordering device). Device back set will change to match the centerline of t...
Not for use in fire rated openings.
You can't run 24VDC into the 12VDC electric strike, over voltage such as this will cause the solenoid to heat up and damage the solenoid.  You must change to a 24V solenoid, part number 050240-00.
The Schlage ES-6400 Electric Strike has been rebranded to Von Duprin 6400 Series Electric Strike, making Allegion’s full electric strike portfolio Von Duprin branded.  All product feature...
Information available at:  http://us.allegion.com/products/system_components/electric_strikes/pages/mortise_cylindrical.aspxOverview, Features and Benefits, Technical Specifications, Wiring In...
Von Duprin does not recommend using XP98/99 devices with any electric strike.   Von Duprin recommends using the standard 98/99 rim device.  The XP device has 2000 pound holding forc...
All of Von Duprin 6000 series electric strikes have continuous duty solenoids either 12 or 24VDC.
The 22, 33/35A and 98/99 rim exit devices: The 6111 is the most common electric strike to be used with these devices 6112 and 6113 electric strikes also could be used The 6300 surface mount el...
Follow these questions to determine which Von Duprin electric strike model you have 1. What type of hardware is latching to the electric strike?   2. Single or pair ...
See Catalog to identify specific model: Von Duprin Electrical Security Products and Accessories Catalog
This is not a recommended application as the electric strike does not have the same holding force as the XP98/99 rim exit device. The electric strike has 1500 pounds of holding force whereas the XP...
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...
The DS is Dual Monitor Switch for Von Duprin 6000 series electric strikes. DS option cannot be added to a Von Duprin 6000 series electric strikes in the field. It is only available factory inst...
The 6300 surface mounted electric strike can be used with a 22 rim device.
The Von Duprin 2670 Guard X does not have a spring loaded latch bolt, it is a dead bolt and will not operate with any electric strikes.
There are no optional monitor switches available for the 6300 electric strike.
A Von Duprin 6111, 6112, or 6113 electric strike will work with a 1790 device.  The 6300 will not work.
Von Duprin now offers an 8827 LBR panic device as of October 7, 2019. This device uses the top rod assembly and soffit latch setup of the fire rated 8827-F device, but has dogging, a UL Panic Har...
Von Duprin offers a PL8827 LBR device with a pullman style top latch and Less Bottom Rod for use with electric strikes, but is not UL labeled nor ANSI/BHMA certified.
LR is the regular/ standard latch and PL is Pullman/ES (Electric Strike) latch for the Von Duprin 8827 exit device.
 ES (electric strike) latch is only used with the 8827 less bottom rod on a non fire rated exit device with a 6111 electric strike.
010055-xx is the part number for Blade Stop Shim kit for 6111 or 6113 electric strike and it must be ordered separately.  xx is for the finish callout.
For all models of 6000 series electric strike, except the 6300 & 6400, the color of the solenoid wires determine the voltage.  Black wires are used on 24VDC solenoids and yellow wir...
The center line of the L9000 mortise lock is 7/8" above the center line of the 6211 electric strike. This is the "C" dimension given on the second page of the 6211 template.
The Von Duprin 5100 electric strike is not for fire rated applications.
Von Duprin 6300 electric strike will operate with 88 rim but not 88F fire rated exit devices.
The Benchmark III control has a 24VDC, 2.5 amp power supply, and built in relay for controlling electric strikes or other accessories less than 2.5 amps current load. For a fail secure strike, r...
The 6112 electric strike is the only strike that will work due to the size of the latch-bolt on the 1590.