von duprin logic board

RELATED FAQS

Question
Answer
The following Legacy information is important to understand before cross referencing power supplies: PS-900 option boards will NOT install onto the legacy power supplies. This includes battery a...
Von Duprin PS914-4RL power supply replaces the PS873-4TD.
The standard Von Duprin PS873 power supply was replaced by the PS914 power supply.
NOTE: The newer PS900 option cards can NOT be used in the PS873 power supplies. The PS873 option cards also can NOT be used in the newer PS900 series power supplies.
  Attached tables are power supply cross reference, power supply option board and power supply option board compatibility. PS900-Model PS900-Summar...
    PS900- Model PS900-Summary Legacy supply (PS873) 900-2RS 2 zone control with sequencing 871-2 b...
  Option Board Von Duprin PS914 Schlage PS902, PS904, PS906 900-2RS Yes No 900-2Q ...
The standard Von Duprin PS873 power supply was replaced by the PS914 power supply.
NOTE: The newer PS900 option cards can NOT be used in the PS873 power supplies. The PS873 option cards also can NOT be used in the newer PS900 series power supplies.
  Attached tables are power supply cross reference, power supply option board and power supply option board compatibility. PS900-Model PS900-Summar...
    PS900- Model PS900-Summary Legacy supply (PS873) 900-2RS 2 zone control with sequencing 871-2 b...
  Option Board Von Duprin PS914 Schlage PS902, PS904, PS906 900-2RS Yes No 900-2Q ...
The SUS can change the logic polarity of the AD400/WRI400 PIM400-TD2 outputs RTX, DPS, TROUBLE, and REN from LOCK/DOOR PROPERTIES Edit tab. You can change High to Low to High using the ed...
  These SUS settings have no effect when the AD400 is linked to a PIM400-485; because the PIM400-485 reports the logic status with RSI-485 commands and not logic levels. The settings are gray...
Some Access Control Panels are designed with “Supervised” or “Dry contact” requirements for the inputs and have no common ground between the ACP (Access Control Panel) and device at the door. “S...
Schlage offers the “RLBD” to support these supervised or dry contact interface applications. The "RLBD" plugs directly into the PIM400-TD2 or PIB300-TD2 for easy hook-up.  
Please reference this Tehnical Note RLBD SES-20120418 for RLBD setup, use information, hook-up diagrams and some testing suggestions when connecting to a Supervised dry contact Access Contro...
This is a link to the RLBD Installation Instructions.
This RLBD data sheet can also be found at Schlage/Technical Support. RLBD DataSheet