von duprin manual

RELATED FAQS

Question
Answer
The programming processes for Allegion devices can be both product and features specific.  Some products programming processes are electronic in nature, others are physical in nature. &nbs...
The 81 service manual can be found here.
The Schlage full size interchangeable core (FSIC) prepped B560F, B561F, and B563F deadbolts all require a UL fire cup (R) in order to be UL listed.  This fire cup is s...
Medeco does offer a key-in-lever cylinder to fit the Schlage ND.You will need to contact Medeco for the cylinderSpecify a key-in-lever cylinder to fit the Schlage ND lock.They will supply a cylinde...
SCHLAGE locks are available with the following backsets: Lock Series Lock Type                 ...
Swapping out the following parts of an ND50 will convert it to an ND53: Swap N123-028 Push button plunger for  N123-017, Push and Turn button plunger Swap N523-000, Push button for N523-001 Pus...
Schlage offers the AL170 single dummy trim, but for applications where a double dummy is needed you can install two AL170 dummy trims back-to-back.  Each AL170 is shipped with a threaded rod (part ...
To convert a L9080EL/EU to a L9082EL/EU you will have to remove and replace the L9080EL/EU lock case and two spindles with the L9082EL/EU lock case and the spindle. See below for part numbers (choo...
The 4600 Series operator has both a 12VDC and 24VDC output rated at 1A (combined load) to power strikes, maglocks, and other devices, but an EL device "always" has to have a separate PS914-2RS Seri...
An electric strike or maglock (24 volt only) can be wired to a Senior Swing 2800/9500 series operator using the P10 Lock Interface cable. To power the 24VDC electric strike or maglock off a LCN Se...
 EL devices are wired to the Senior Swing, using the P10 (761465) cable.  Connect the "GRAY" wire to the SC terminal on the 900-2RS card in the Von Duprin Power Supply and the "VIOLET" wire to the ...
First, turn off the power to the Senior Swing. If the door closes, check controller for a constant activation signal from an activation device. If door continues to hang up and will not close...
The older model Senior Swing came with 2 spring options. The "standard force" spring required 15 lbs of manual  opening force, and reduced force "RF" required 11 lbs of manual opening force.  All S...
LCN does offer a 2810 Senior Swing / 2010 manual closer combo for a pair of doors.  Both units contained within the same Senior Swing header. To order a paired operator with a 2810 on&nb...
The Senior Swing has a built in circuit that controls closing speed through the motor. If the door is slamming, there must be a broken gear in the gearbox and the gearbox will need to be replaced.
Surface Mounting - A 9542 DD (double door) header and a 9540-18 mounting plate can be used on the active leaf. A manual closer with a PA (parallel arm) can the be installed on the inactive leaf.  B...
A Senior Swing operator can be hard to open manually if "Power Boost" feature is turned on, and programmed to the Cn (continuous) setting. To make the door easy to open manually, turn the "Power Bo...
The 4630/4640 Series operator is designed/recommended for a door that will see mostly manual traffic with the occasion automatic/ handicap operation.
The manual opening force on a 4630/4640 will be approximately 8.5 lbs to 14 lbs depending on the spring setting.
The manual opening force to required to open a Sr Swing operator is approximately 11-12 lbs.
To convert a Senior Swing 9550 to a 9560: Remove the companion harness (9550-982) from one of the motor/gearboxes in the 9550. Install a second control box, and connect it to the motor/gearbox t...
The 9550 series Senior Swing WILL NOT work on a pair of doors with auto flush bolts. The 9560 series Senior Swing and a sequence module are required when used on an pair of door with auto flush b...
Parts required to convert a 4640 to a 4630: 4630-3971 cylinder. 4630-3077T  track arm. 4630-3038 track. 4630-WMS screw pack,which includes the -3034 roller. Parts required to convert a ...
The installation of the arms with the Benchmark and Falcon Swing Door Operator is similar to the Sr. Swing Series . The arms are installed with the main activation input shorted, the gearbox at the...
The 8310-877 Bodyguard Safety Sensor attaches (plugs in) to the P1 connector on the Senior Swing controller. The 8310-846 (761462-00) wiring harness "included" with the 8310-877 safety sensor is us...
How to Order: The Senior Swing header is ordered by the width of the door(s). The measurement from inside jamb to inside jamb of the frame. If the Senior Swing header is ordered the wrong length, ...
The "Fire Alarm" indication occurs when there is no connection across terminals 13 & 14. Check to verify that the "Fire Alarm" shunt (R1 jumper) on the I/O board has not been cut. Install jumpe...
An error - E04 - is an indication of a constant activation input from either the "Hold Open" switch or a "Wall Activation" switch when the 4600 power is turned on. This condition also occurs when l...
The only difference between the 9130 and 9140 Benchmark operators are the arms. To convert a Benchmark 9310 (pull) to a 9140 (push), order a 9140-3077 push arm assembly. To convert a Benchmark...
On a single door take the mounting dimensions from centerline of pivots.  On a pair of doors, depending on the door width and pivots being used, the operators can butt up against each other or ov...
When installing the arm; the gearbox shaft and door must be at the (+90°) full open position. The following step are used to install the Senior Swing (STD) pull arm. Install the header using app...
When installing the arm; the gearbox shaft  and door must be at the (+90°) full open position. The following step are used to install the Sr. Swing (REG) push arm. Install the header and door brac...
The 4630/4640 operator can accept any ( normally open / dry contact) actuator - hardwired or wireless.  LCN Wireless actuators require the use of the 8310-865 RF receiver.The 8310-856 RF ...
The current (digital control box) activation input wiring harness (# 761464-00) is included in the Sr. Swing parts bag (-518), and has 4 wires in it, Black, White, Yellow, & Gray. This harness p...
The 4630/4630 operator has a 12 VDC and 24 VDC output that can power an electric strike or maglock. The wiring diagrams are shown on page 14 of the installation instructions (attached). 4600 Insta...
The current Powder Coat finishes are: Aluminum (BHMA 689) Dark Bronze (BHMA 695) Brass (BHMA 696) Light Bronze (BHMA 691) Statuary Bronze (BHMA 690) Black (BHMA 693)For list of standar...
Tan Powder Coat can be ordered but only available as a special finish with a metal cover.
White Powder Coat can be ordered as a special RAL finish with a metal cover.
For custom powder coat (LCN RAL customer powder coat colors) guide/chart please see here.
LCN does not does not have or supply any information for the old (obsolete) "High Energy" Dor-O-Matic Sliding doors, Bi-Fold doors or Astro Swing doors. You MUST be AAADM certified to work on, or g...
There are 2 wiring diagrams for sequencing a double door vestibule application shown on page 13 of the 4630/4640 installation instructions.
The 8310-865 RF receiver contacts (N.O. and COM) would connect to terminals 15 & 17 (the alternate action input) on the 4600 operator. The first activation would open the door, the s...
All Senior Swing models are heavy duty operators and have the Push-N-Go (PNG) feature.  This feature is a programmable function in the control module.  The PNG settings are: Off, On, or FD (fixed)...
To check the clutch on a 4600 Series operator: Follow the wires from the clutch to the 4 pin connector on the controller, and disconnect the connector from the control box. Clutch -- Measure th...
The Senior Swing has an optional (plug in) Off/Auto/Hold Open switch available. The 8310-806R (rocker switch), or 8310-806K (key switch). CANNOT use switch by others, requires a special (center - n...
The Senior Swing operator is designed to power open the door to 90°. The built in dead stop (in the gearbox) prevents it from opening any further. If the Senior Swing operator is opening to far (pa...
Yes. Remove the receiver from the operator. Remove the transmitter from the actuator button. Attach 1 wire to the NO (normally open) contact on the actuator switch, and another wire to the COM (com...
The 8310-877 comes with a 6 wire cable. You have to cut the connectors off both ends and hardwire it to the 4600 operator as follows: The 6 wire cable connections to the 7 pin connector in the 8310...
First you need to determine if the closer is handed.  A handed door closer will only have a single shaft on one side of the closer for the arm to attach to. If the closer is handed...
The 4600 Series I/O PC Board was updated in Nov. of 2010. As part of that update, the hold open switch plug in connector was removed, requiring the hold open switch to be field wired on t...
The 4600 operator is designed to meet the ANSI Code 156.19 that limits the opening force to a 15 lbs.  By code and design, the operator must stop opening the door when an obstruction or resistance ...
The Benchmark III control has a 24VDC, 2.5 amp power supply, and built in relay for controlling electric strikes or other accessories less than 2.5 amps current load. For a fail secure strike, r...
Use the PS902-2RS power supply with LCN auto operator on single door, PS904-2RS power supply on double door and PS904/906-2RS-2RS for 2 pair of QELA is required for basic operation with a...
If arm screw is not gripping the forearm tube enough to securely hold the rod and shoe in place: If the allen head on the arm screw (-83) is stripped out, try using a wrench to tighten it. Try ...
If manually it opens and closes fine, check to make sure one of the actuators is not getting stuck in the on position. Verify that the "Operating Indicator" LED's -- "POWER and SAFETY CLEAR" LED's ...
The companion cable can be ordered as a 9550-982 or a 2850-982, the same cable is used on both models.
The 4600 is designed for an opening with (MOSTLY) manual traffic, and the (OCCASIONAL) automatic activation. The Senior Swing is designed for an opening with (MOSTLY) automatic activation, and (OC...
If a 4600 clicks, but won't open the door: Verify proper connection of all the control box connectors. Verify correct manual operation of door. Verify actuator connections and any strike/maglo...
The LCN closer fluid "Liquid X" will perform without variation between:  -30° F to +120° F - for manual closers.  +35° F to +120° F - for electrical closers and automatic operators. At around ...
 Pneumatic Automatic Operators are used in areas where electrically operated devices are not convenient or permitted.  Consists of a modified, heavy-duty door closer for manual oper...
The 4040(XP) door closer can be used as a temporary replacement in a 4630/4640 operator to provide manual control of the door while the 4630/4640 closer cylinder is being repaired or a replacement ...
Special Rust Inhibitor (SRI) - is a pretreatment that is applied to the metal components prior to the addition of the LCN powder coat finish, standard or custom. ...
ElectroMechanical Automatic Operators are designed to automatically open when activated. The Benchmark Series are Medium Duty "Commercial" automatic operators, often used on of...
A 4600 (4630/4640) not opening to a full 90 degrees could be caused by a couple things: The Opening Force could be set too low. Try increasing the opening force adjustment on the controller a 1/...
Cam Lift hinges can only be used with LCN door closers that have a "Regular" style arm.     Manual Closers: Maximum lift dimension is 3/4". Can not be use EDA, CUSH, or Track Arm do...
Electro-hydraulic Automatic Operators are: Designed for manual opening applications where there is occasional need for automating the door to meet ADA requirements.  Electrically powere...
If an Size 1 (ADA) closer is set to 5 lbs. opening force, it will only have about 3 lbs. (60/70%) closing force. If the closer will not close against air pressure, but the ADA requirements have to ...
The hydraulic closer underneath the control box has 3 regulating valves (like any 4040 series hydraulic closer). Main Speed - adjust closing speed from 90° open down to 10°. Latch Speed - adju...
The Benchmark and Falcon operator gearbox assemblies are not repairable. The gearbox belt and/or pulley cannot be replaced in the field, the gearbox would need to be replaced as a complete assembly...
To adjust the hold open time on a 4600 (4630/4640) operator: Press the "MODE" button on the control box 1 time to get into programming mode. The "YELLOW" mode indicator LED next to "HOLD OPEN TI...
The 4600 hold open switch (for the new 1-24 single terminal strip I/O board) wires into terminals 2 and 6 or 4 and 6.
If you have an old digital 4630 or 4640 operator with an I/O Board assembly that has two terminal strips, one with terminals 1-12, and the other that has 13-24 and you are in need of replacing the ...
The 8310-865 RF receiver connection to the Falcon 8200 operator are: RED and BLACK power wires on the receiver connect to the 12V AC terminals on the Falcon operator. The WHITE wire from the COM t...
See Point to Point wiring diagram here.
There is a total of 4 red buttons on the front of the Senior Swing control box. To turn on the display, press and hold any 2 of the 4 red buttons at the same time for approximately 3-5 seconds. Y...
The 8310-845 Timer/Sequencer is required to sequence two Senior Swing operators. The 8310-845 will need to be programmed to "Function 65" for the sequencing feature.