The 4040XP, 1260/1261, 1460/1461, 4030/4031 closers have the tri-pack mounting option when ordered with an Rw/PA or Hw/PA designation.
All of the Everest D sections/keyways are restricted.
Key removable option is not available for any of Von Duprin aluminum mullions.
The RX monitors the push bar while the LX monitors the latch bolt of the exit device. A SS device has an LX and a key cylinder switch plus an emergency push bar signage.
Von Duprin offers two options:The CDSI/HDSI Dogging Indicator provides an at-a-glance verification of the status of the door from inside of the room. Visible “LOCKED” and “UNLOCKED” indicators show...
The old 800 series power supplies and boards and the new 900 series power supplies and boards are not compatible with one another.
The PS900 power supplies will only accept the 900-XX option boards.
Communication takes place between the 2Q option board and the Von Duprin QEL exit device.  If this communication does not occur then the device will not retract.  The 900-2Q board is not ...
SD option is available and is also standard with Von Duprin 98/99 rim and vertical rod exit devices but not available with mortise device.
Product Ordered after 7/10/2012 - Product identified by label on QEL motor You no longer need to use the 900-2Q option board (no longer available) with the PS900 power supplies to ...
Product Ordered before 7/10/2012 - Product identified by no label on QEL motor. You must use the 900-2Q option board with the PS900 power supplies to operate the QEL devices.  The attached ta...
The cam is not inverted on the mortise cylinder for the CD option.
The current Von Duprin ALK comes standard with the External Inhibit feature.
SD is Special cylinder dogging in the center case of 98/99 rim and vertical rod non fire rated devices and is available with standard, EL, QEL, CX and ALK.
To order Von Duprin exit device reference the "Additional information/How to order" section in the Von Duprin catalogs. All Von Duprin device series Catalogs are available on website.
The Von Duprin CD kit comes with the cover plate machined to accept the cylinder dogging mortise cylinder.1 1/4" mortise cylinder with an inverted straight cam is required for CD option on Von Dupr...
Double cylinders are only available on Von Duprin 98/99 Rim and 98/9975 Mortise devices.
You can not use these options together on the same device per the following reasons: QEL/EL device retracts the latch bolt of the exit device allowing entry. CX (Chexit) device ...
We no longer offer a delay egress board in the P900 series power supplies.
The delay egress is controlled in the exit device (Von Duprin Chexit), the magnetic lock, or other locking device.
The 1461 Rw/PA requires a 4-3/8" minimum top rail on the door without the use of a drop plate.  If top rail is less than 4-3/8" a 1460-18PA drop plate will have to be used.
ST Number Product 1 Product 2 Description ST-2776 ...
Regular Arm with Parallel Arm Shoe
Parallel Arm
Hold Open Arm with Parallel Arm Shoe
Narrow Frame, PA Mount, Parallel Arm Mount, Parallel Arm Installation, PA Installation
PA Mounting, Parallel Arm Mounting
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.
The 4041 Rw/PA and the Hw/PA have the same template.  The only difference is the arm. The 4041/4040XP Hw/PA, if mounted to the 180° template, will hold the door open at 180°. Rw/PA is Regular A...
The Rw/PA arm is simply a regular arm that is packed with a 62PA (parallel arm) shoe, which will allow a (Tri-Pack) closer to be mounted in a regular, top jamb, or parallel arm application.
Optional closer reinforcements are located at 3" from hinge jamb to the beginning of the reinforcement plate. This applies to Regular Arm, Parallel Arm, Top Jamb. Regular Arm (RA) closer reinfor...
To install a 4041/4040XP with Rw/PA or Hw/PA arm, you need a minimum of 5-3/8" top rail on the door, measured from the bottom of the stop. If the top rail is less than 5-3/8", you will need to use ...
The 4040 Rw/PA can be mounted 3 different ways. The 4040-18 drop plate is used for the regular pull side mount. The 4040-18TJ drop plate is used for the top jamb push side mount. The 4040-18P...
When placing an order for a 4041/4040XP Rw/PA with hold open, it would be ordered as a 4041 /4040XP Hw/PA. For an existing Rw/PA requiring the addition of a hold open function, a hold open arm woul...