The RX monitors the push bar while the LX monitors the latch bolt of the exit device. A SS device has an LX and a key cylinder switch plus an emergency push bar signage.
The Von Duprin 7500 mortise lock body ships in the NL mode.  Either the function of 7500 lock body has not been changed to the Classroom function or the NL Drive screw is not all the way down. Step...
  Tips for changing the function: The NL Drive screw will not be visible when lock body is set to Classroom function There is locktite on the screw that makes it seem like its turned down enou...
The following steps are required to convert the Von Duprin 98/9975L from classroom to night latch function: Order new 996L-NL-M trim and reset NL drive screw in mortise lockbody as se...
Recommend to order a new 990NL-R/V or M trim to change from TP/Classroom function to NL/Storeroom function. You will also need to reinstall the NL drive screw back into into the mast...
To convert the Von Duprin 9975NL(Night Latch or Storeroom) to 9975L (Classroom) exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL ...
To convert the Von Duprin 9975L to 9975NL exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory): Turn the NL screw on 7500 mortise lock counter clo...
The signal switch(S) will automatically be installed in an EL1490 and EL1590 devices when built at factory. Red, Green, and Black are the wires to the switch and are shown in the 1490 instructio...