23848385 is the part number to order for the COM400 radio board that has the MCX jack for the optional RF antenna. It is shipped in the PIM400 and WRI400 so if needed for the wall mounted module yo...
The only difference between the COM400 in a door lock (AD400) and the COM400 in a wall mounted interface module is the MCX jack, which is provided for the optional remote RF antenna when needed o...
The COM400 has only two versions of FW, 2.2a and 2,2d and they are cross compatible and completely functional with all AD-Series wireless devices. There is no reason to change a FW 2.2a to a FW 2...
Always check the most current revision of the ANSI A156.19 standard for recommendation or requirement of the location of a Knowing Act switch. 2019 ANSI A156.19 states the requirement of the ...
The following anchors are approve for use in FEMA Tornado Resistant openingsMasonry walls:Jamb anchors - Wire masonry anchorsSill (base) anchors - Adjustable base anchorsExisting walls:Jamb an...
Overhead Stop, Floor Stop, Wall Stop, Stop
The rough opening dimensions are the same for either Welded (SUA) or Knock Down (KD) frames For F, FN, FE, DE, MU three sided frames and four sided borrowed light frames: New masonry W...
 For DW, K three sided frames and four sided borrowed light frames: Three sided frame = door opening width (order size) plus 1 1/2" minimum to 2" maximum and the door opening hei...
1-1/8" at door face, 2-3/8" at widest point, 3-1/2" depth, with 1/8" thick walls.
The keycam may have failed, example here, the latest design keycam can be easily identified as the colored changed to black. Replace either the keycam or chassis as needed...
 This could also happen if the tailpiece isn't installed in a KIL, FSIC, or SFIC cylinder.  The FSIC driver also could have come loose from the core in the spindle.
Yes, Steelcraft doors and/or frames are available and can carry a UL, WH or FM label. The type of fire label (UL, WH or FM) is dictated by the specifications and local building code. Doors ...
Hold Open Closers & Magnets (Fire/Life safety products) provide a wide range of solutions.  Single or multi-point hold open closers Utilize an electromechanical closer. Hold the door o...