This option is not available as there is no NL cam to directly drive the rods and using a key to lift the heavy stainless, brass or bronze rods would damage the key.
The 388 Cylinder Control is required for the NL-OP function on a 33A/35A series exit devices.
The 110NL is used on 22 and 98/99 series exit devices not 33/35A series devices.
This is possible: For metal doors prep door according to the 24R/V NL-OP Template or the 25R/V NL-OP Template and for wood doors use 24R/V NL-OP Wood Template or 25R/V...
The NL-OP function for 25-C uses the 718C trim, so template T-2211 for metal doors and W-2211 for wood doors for 718 trims prior to 2/28/2011.
T-2211 for trims prior to 2/28/2011
W-2211 for...
No, the 98/99 series mortise exit device should be ordered as NL less trim. IE, 9875NL-L/TRIM. NL-OP suffix is normally used with the 98/99 series rim, surface and concealed vertical rod devices wh...