What electric strike works with falcon

RELATED FAQS

Question
Answer
The 5547 device can be ordered with an ES prefix to work in conjunction with an electric strike. This requires LBR and can only be done on non-fire rated applications. To convert an existing ...
Von Duprin doesn't offer any electric strike to fit into 1 1/2" aluminum/metal faced frame.  Minimum requirement to install 6211/6211AL is 1 15/32" mortise depth.
Von Duprin 6223 electric strike is the most common closed back strike or the 6221 for open back strike on inactive leaf that can be used with Schlage L9000 or Von Duprin 7500 mortise lock.
The Von Duprin 2670 Guard X does not have a spring loaded latch bolt, it is a dead bolt and will not operate with any electric strikes.
The Von Duprin 6210 electric strike was designed for retrofit applications and will not work with the Falcon MA series lock when strike and lock body are mounted at standard locations (centerline o...
The following application information apply to the 5100 electric strike: Can only be used on a single door with a cylindrical lock Can not be used on a pair of doors Can not be used on a mullion
The 5100 strike details are listed below: Only operates with 12VDC or 24VDC power supply. Will not operate with AC transformer. 12 or 24VAC can be converted to 12/24VDC using Von Duprin SO12 o...