Only the Schlage ND-Series can be prepped to accept non-Schlage cores.
All designs are supplied with the appropriate tailpiece
Non-Schlage cores are NOT included
Lever designs available vary d...
The letters GD, HD, BD, or BDC should be put after the lock function. EXAMPLE: ND53BD
GD = Schlage SFIC core
HD = Construction core
BD = Less core
BDC = Plastic temporary construction core
On ND locks manufactured on or after January 30, 2017 only the SFIC lever and SFIC driver are needed to convert the lock from Full Size conventional (PD) or Full Size IC (JD, RD, TD) prep to S...
On ND locks manufactured prior to January 30, 2017, the lever, spring cage and tailpiece needed to be replaced with the SFIC lever, SFIC spring cage and the SFIC driver . N123-056 - Outside sp...
The lever removal tool can be used to remove levers in both the ND and the L Series mortise locks.
On August 15, 2012 Schlage began shipping a new, more ergonomic, lever removal tool to coincide with Phase 1 of the ND-Series improvement project. This tool can be used for Schlage ND-Series ...
Von Duprin 98/99 NL drive screw is located in back of the 98/99 center case assembly.
NL drive screw should be left in with trim lock slide plate in up position in the 98/99 exit device with E99...
Order the M204-198 thru-bolt jig, see Figure 1.
Figure 1: M204-198 thru bolt jig
The 40-080 was the old Schlage jig. The 030736-000-70 was the old Falcon jig. When the jig changed to...
According to ANSI specifications for cylindrical or mortise locks:
The lock strike centerline should be 40 5/16" from the bottom of the frame with the lock in relation to the strike.&...
ND -series locks manufactured on or after January 30, 2017 use the following spring cages:Outside - N523-218 - For ALL cylinder options except for JD-YA6, JD-YA7 and JD-MEDInside - N523-222 -...
ND-series locks manufactured before January 30, 2017 used the following spring cages: