when is LCN Fire closer required

RELATED FAQS

Question
Answer
Closers mounted according to LCN installation instructions require no periodic maintenance or seasonal adjustments.  Monthly, quarterly, and annual visual inspections are recommended for Fire/...
The 330 closer and parts were discontinued in early 2009. LCN does not have any parts available for the 330 series closer. The LCN 3030 Series would be the comparable closer replacement to the...
There are a few things that can cause a closer to slam. The closer could be adjusted incorrectly. Turn all regulating screws clockwise until they stop. Then open each valve 1 and 1/2 turns. If t...
Regular LCN closers have "3" regulating valves for General Speed, Latch Speed, and Backcheck. If the LCN closer has "4" regulating valves, then the closer has the Delayed Action feature. De...
The LCN "Traditional" series closer line was discontinued in 1980.  
Cam Lift hinges can only be used with LCN door closers that have a "Regular" style arm.             Manual Closers: Maximum li...
LCN started putting on the green dials for the spring adjustment on the 4041's in 2001.
STANDARD ROD AND SHOE: 4020, 4031, 1460, 1520, 1370, 1070, 1260, 4640, 4820 is: 8 3/8” LONG ROD AND SHOE: 4020: 4031, 1460, 1520, 1370, 1070, 1260, 4640, 4820 is: 12 3/8” STANDARD ROD AN...