The resistance readings for a Falcon 24 or 25 Series EL solenoid should read;Green to Yellow = Pull Coil, should measure between 1 and 2 ohms of resistance. Green to Orange = Hold Coil, s...
The Falcon 8200 series operator has a circuit that shuts down the operator when a resistance of 15 lbs. occurs, so the operator will not be damaged.
ANSI grade one cycle test is 500,000, grade two is 250,000 and grade three is 100,000.
       "Opening Force" adjustment could be set to strong (high).  This adjustment is a turn pot adjustment which can be found on the controller.  Try adjusti...
The American National Standards Institute (ANSI) and Builders Hardware Manufacturers Association (BHMA) have developed durability, strength and performance standards for every type of door hardware...