Where can I find installation instructions for old closers

RELATED FAQS

Question
Answer
The LCN "Traditional" series closer line was discontinued in 1980.  
To install a Schlage ND170 click here for the installation instructions.
The 1370 series closer was discontinued on Oct. 4th, 2008The 1260 closer hole pattern is 9-1/16" x 3/4", which is NOT the same hole pattern as the 1370 closer. The 1260-18QF plate does have the s...
The 62A shoe is used when it is necessary to install the door closer (lower) down on the door so that it will operate under accessories such as overhead stops, coordinators, etc.
A  LHR (left hand reverse) door uses a RH (right hand) door closer. A RHR (right hand reverse) door uses a LH (left hand) door closer.
A door can be handed in several ways. The easiest way is to stand on the Push side of the door. Push the door away from you as if you are going to walk thru the opening. If the hinges are on yo...
To determine the hand of a door, view the door from the outside, security side or key side of door.  Once there identify which side are the hinges located on the, right or left side of t...
Go to the push side of the door opening.  See above illustration. If door swings out to the left, it needs a left hand door closer. If door swings out to the right, i...
The standard screw pack for an LCN closer is the SRT (Self Reaming and Tapping) screw. Thru bolts are an option, but must be specified on the order. There is no charge for them, but they do need to...
 The correct method (process) for setting the hold open is: The 4010 hold open arms are handed, verify correct hand arm. (R or L stamped on main arm) Loosen the hold open nut. Opened the door ...
The 1260 closer body has the same footprint (9-1/16" x 3/4") and it mounts in the same location as the 1070 body, but the arm will have to be moved slightly to match the 1260 templating.
 The P1070 was replaced with the 1261 Rw/PA.
Hold Open Closers & Magnets (Fire/Life safety products) provide a wide range of solutions.  Single or multi-point hold open closers Utilize an electromechanical closer. Hold the door o...
Regular LCN closers have "3" regulating valves for General Speed, Latch Speed, and Backcheck. If the LCN closer has "4" regulating valves, then the closer has the Delayed Action feature. De...
Closers mounted according to LCN installation instructions require no periodic maintenance or seasonal adjustments.  Monthly, quarterly, and annual visual inspections are recommended for Fire/...
How to:  What are the steps to adjust a door closer?Facts: All LCN and FALCON door closers will have 3 regulating valves and a spring adjustment.  All closers with a "Delay" feature ...
Surface Mounting - A 9542 DD (double door) header and a 9540-18 mounting plate can be used on the active leaf. A manual closer with a PA (parallel arm) can the be installed on the inactive leaf.  B...
The date stamp on a 4041/4040XP is on the packing nut.  The date will be the week of the year and then the year. EXAMPLE: 10 05 would be week 10 of 2005.  For example see...
Attach is the instruction and template for 237L device, 237 Instructions.
To remove the Schlage L Series from a door reference the appropriate installation instructions found here at https://us.allegion.com/en/home.html
19 Series Installation Instructions page.
This information can be found at the following URL's: AD200/AD250/AD300/AD400 Cylindrical http://w3.securitytechnologies.com/irstdocs/installinstructions/102104 P516-092.pdf
AD200/AD250/AD300/AD400 Mortise http://w3.securitytechnologies.com/irstdocs/installinstructions/102106 P516-093.pdf
AD200/AD250/AD300/AD400 Cylindrical Exit http://w3.securitytechnologies.com/irstdocs/installinstructions/102264 P516-094.pdf
AD200/AD250/AD300/AD400 Mortise Exit http://w3.securitytechnologies.com/irstdocs/installinstructions/102263 P516-095.pdf
CO100/CO200/CO250 Cylindrical http://w3.securitytechnologies.com/irstdocs/installinstructions/104214 P516-266.pdf
CO100/CO200/CO250 Mortise http://w3.securitytechnologies.com/irstdocs/installinstructions/104213 P516-267.pdf
CO-Series Cylindrical Exit http://w3.securitytechnologies.com/irstdocs/installinstructions/102297 P516-268.pdf
CO-Series Mortise Exit http://w3.securitytechnologies.com/irstdocs/installinstructions/102296 P516-269.pdf
  For Product Shipped Prior to August 2012 using the old (black) potted module: a.       0-100 ft 14 gauge wire b.      0-200 ft 12...
 
Steelcraft offers two optional types of reinforcements for open section header to be installed in distributor shop or in the field: Full profile sleeve; is a 14 gauge, 16" long part to fit the p...
 Von Duprin surface mounted 6300 electric strike paper template and installation instruction are provided with the electric strike. See attached 6300 Template & I...
Data sheets and installation instructions for 900 series power supplies are available at http://us.allegion.com/Services/TechSupport/Pages/home.aspx?ps=Electronic%20Security&pc=Electronic%...
The 4110 closer is handed, and will have an "RH" and "LH" on the casting next to the closer shaft. The regulating valves are going to be on the same side as the hand of the closer.
To determine the SC series, measure center to center on the closer body bolt hole mounting pattern and an overall description of the closer and arm. SC91 -- 6-3/8" x 3/4" -- unique arm SC93 -- 9-1...
The link to the specific sheet can be found by clicking here:  http://us.allegion.com/content/dam/allegion-us-2/web-documents-2/InstallInstructions/Von_Duprin_PS914_Power_Supply_Installation_I...
It is always recommended to point installers to the industry installation manuals which are very comprehensive and are ANSI documents. SDI (Steel Door Institute) installation manual can be found...
When placing an order for a 4041/4040XP Rw/PA with hold open, it would be ordered as a 4041 /4040XP Hw/PA. For an existing Rw/PA requiring the addition of a hold open function, a hold open arm woul...
If an Size 1 (ADA) closer is set to 5 lbs. opening force, it will only have about 3 lbs. (60/70%) closing force. If the closer will not close against air pressure, but the ADA requirements have to ...
Special template ST-2211 is used to mount a 2030 series closer with a GJ 70,79,81,90, and 450 series overhead stops. This ST works with any GJ "surface" mounted stop. The 2030 closer cannot b...
There are a few things that can cause a closer to slam. The closer could be adjusted incorrectly. Turn all regulating screws clockwise until they stop. Then open each valve 1 and 1/2 turns. If t...
First you need to determine if the closer is handed.  A handed door closer will only have a single shaft on one side of the closer for the arm to attach to. If the closer is handed...
The regulation valves are designed to adjust the flow the hydraulic fluid in the closer which regulates the door closing speed through various phases of the closing cycle. The regulation valves h...
The hold open position on a "REG" or "EDA"  hold open arm is set with the door to a few degrees shy of the desired hold open point. To properly set, open the door 5° less then the desired hold open...
Please refer to the Allegion Contact Us web page for all inquiries in North and South America.Contact Us for Europe, Middle East, India, Africa and Asia Pacific,  You can also r...
Out of plumb (also referred to as twisted) frames usually cannot be adjusted. "Out of Plumb or Twisted frames (or jambs)" is a condition created by improper wall construction and/or improper insta...
It is the responsibility of the installing contractor to install all material in accordance with SDI or HMMA installation standards and tolerances. Out of square frames which are installed out of t...
Industry standards for hollow metal frames installation tolerances have been developed by both the SDI (Steel Door Institute) and HMMA (Hollow Metal Manufacturers). Both standards are based on the ...
Yes, a filler plate can be used to cover an EPT prep as long as it is made from the same material as the frame. This information can also be found in NFPA 80 under Chapter 5 for Field Modifications.
Incorrect timing of the lock can cause the outside lever to retract the latch when raised up.  See instructions here (Step 16 and 17) to time a T351, T381, T561, and T571.  Also applies to the same...
To verify the timing on a T561, function test the outside lever after locking it.  To lock the key should only rotate 180 degrees (Not 360 degrees as Schlage does) A properly timed lock will n...
Chexit devices shipped after 8-24-2015 with motor driven:Attached is the installation instructions of the the Von Duprin Chexit devices that includes the wiring diagrams.Installation Instructions&n...
Chexit devices shipped before 8-24-2015 with solenoid driven:Attached are the single and double door wiring , cable voltage reading documents for trouble shooting, and the installation in...
The Falcon Exit Alarm option was updated in June 2012 to include the following benefits. Louder Alarm 95dbs vs 87dbs Easier battery changes 24Vdc hardwire(HW) option included w/ standard board...
Select the appropriate installation instructions below for step-by-step guidance on how to install a Schlage ND lock.  ND-Series Installation InstructionsND25 Installation InstructionsND170 Insta...