where does steelcraft put fire labels on frames?

RELATED FAQS

Question
Answer
Yes, Steelcraft doors and/or frames are available and can carry a UL, WH or FM label. The type of fire label (UL, WH or FM) is dictated by the specifications and local building code. Doors ...
Fire labels (UL, ITS/WHI or FM) are located as follows: Butt Hinges and Pivots: On the doors the fire label is located on the hinge edge between the top and 2nd hinge preparation. On the fram...
ASTM E-119 is a test standard for walls, partitions and floor or roof systems: This test standard is also used for ceramic type glasses when used as window wall and/or borrowed light frames. ...
The UBC (Uniform Building Code) was a regional legacy building code which was superseded in most jurisdictions by the IBC (International Building Code). There may be some areas of the country which...
Drywall Slip-on Frame is an industry term describing a 3 sided frame designed to be installed on a wall composed of steel or wood studs with gypsum board or other facing material and is i...
Maximum hourly rating for a transom and side light or panel frame is 1 1/2 hour (90 minutes). In masonry wall application the maximum is 13'6" x 12'2" In stud wall application the maximum is 13...
A Dutch Door is a door having two separate leaves, hung one over the other: Usually equipped so that both leaves can be operated Usually in single doors applications but sometimes specified ...
The 20 minute Fire Rating is a valid label and are commonly referred to as "Smoke and Draft control door assemblies". Depending on the local fire code and the openings's applica...