Which closer should I use for an exterior application?

RELATED FAQS

Question
Answer
Surface Mounted door closers are the most durable and common type of door closer. Mounted to the surface of the door or frame Can be configured (through installation or arm type) to meet a...
The valve on the back of a 4041/4040XP closer is a "Back Check Selector Valve" that needs to be turned in on "Parallel Arm" mount applications ONLY. If a 4041/4040XP closer mounted "Top Jamb", or "...
A 4110 with AVB (advance variable back check) would be recommended. Using a SCUSH (Spring Cush) arm will also help minimize shock to all door hardware.
Exit alarm ALK devices are not recommended for exterior application. We do not offer water proof exit alarm ALK devices.
Most Panic devices are not designed for exterior applications. As with any mechanical device, exposure to the elements may affect the operation and life of the device and/or finish an...
Electric strikes are not water proof an not recommended for exterior application especially gates.
The LCN closers are not designed nor intended to be exterior mounted in the elements.  