Standard and Full Size I/C mortise cylinders on the L9485 and L9486, Hotel or Restroom Locks, use the concept of a ward ring to lock out all change keys once the deadbolt is thrown. Instead of a fu...
HANDINGA stop ring is installed on the right side for right hand operation and on the left side for left hand operation. Right hand shown below.
Apartment
Corridor Lock function is defined as a lock where the latch bolt operated by
lever from either side, except when outside lever is made inoperative by a stop
or mechanical means other than...
ND-Series Cylinder Reference Table
Function
Door Thickness
Cylinder Mechanism
Complete Cylinder
Non-Hotel Functions
Standard
Conventional
23-065
Primus
20-765
Pri...
Refer to table 1 for the list of Schlage AL-Series cylinders.
AL-Series Cylinder Reference Table
Function
Cylinder Mechanism
Complete Cylinder
Non-Hotel Functions
...
Night Latch (NL)= key retracts the latch momentarily to allow entry. When key is removed, the latch will extend and locks the door (momentary unlock).
Class Room (Lock/ Unlock)= key unlocks...
To convert the Von Duprin 9975NL(Night Latch or Storeroom) to 9975L (Classroom) exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory):
Turn the NL ...
To convert the Von Duprin 9975L to 9975NL exit function follow these steps (Note: the mortise lock is shipped as Night Latch from the factory):
Turn the NL screw on 7500 mortise lock counter clo...
Key in lever
Falcon cylinders do not work in Schlage locks. The cylinders may fit, but there are no specific tailpieces created to operate any Schlage lock.
SFIC
SFIC is universal so Falcon and...
Hotel cylinder in L9000
As long as the correct cam is used (Schlage clover), a Falcon Hotel cylinder will properly function in an L9486 hotel lock.
L9485: Latchbolt retracted by key outside or by knob/lever inside. Outside knob/lever always fixed. Deadbolt thrown or retracted by inside thumbturn. When deadbolt is thrown, all keys become ino...
Communicating Frames are hollow metal frame fabricated such that a door is installed in each rabbet of a double rabbeted frame (2 doors total) to facilitate dual access and control of the opening, ...