Only the Schlage ND-Series can be prepped to accept non-Schlage cores.
All designs are supplied with the appropriate tailpiece
Non-Schlage cores are NOT included
Lever designs available vary d...
As of August 26, 2013, the ND75/95 in 626 finish comes standard (no additional charge) with indicator rose with black lettering and indicator arrow.For locks that shipped prior to August 26, 2013, ...
Component
Function
Product
How to Order
Rhodes Indicator Rose
Classroom Security
ND75, ND95
XN12-035 (626 only)
Omega Indicat...
See attached bulletin. Marketing bulletin with associated Von Duprin indicators listed.
If a blank rose is preferred over an indicator rose, the customer will need to order the lock less inside rose and order the inside rose (03-042) separately. Example: Lock Less each rose: Use ...
The ND12 and ND25 are both exit locks.ND12 Outside lever always fixed. Insidelever always unlocked for immediateegress.ND25Blank plate outside. Inside leveralways unlocked for immediate egress.
The letters GD, HD, BD, or BDC should be put after the lock function. EXAMPLE: ND53BD
GD = Schlage SFIC core
HD = Construction core
BD = Less core
BDC = Plastic temporary construction core
On ND locks manufactured on or after January 30, 2017 only the SFIC lever and SFIC driver are needed to convert the lock from Full Size conventional (PD) or Full Size IC (JD, RD, TD) prep to S...
On ND locks manufactured prior to January 30, 2017, the lever, spring cage and tailpiece needed to be replaced with the SFIC lever, SFIC spring cage and the SFIC driver . N123-056 - Outside sp...
A and AL product: Must use the 2 3/8" backset with the 41-005 extension link
D Knob and ND product: Must use the 2 3/4" backset with the 43-005 extension link
ND-Series Cylinder Reference Table
Function
Door Thickness
Cylinder Mechanism
Complete Cylinder
Non-Hotel Functions
Standard
Conventional
23-065
Primus
20-765
Pri...
HIGH SECURITY
Primus/Primus XP: In addition to six cuts for standard locking mechanism, there are five side finger pins to operate the secondary sidebar lock. Primus keys will operate non-Pri...
Falcon D series deadbolts will not accept Schlage Key-in-lever cylinders. The faceplate plug hole is smaller in diameter than the Schlage plug and does not fit flush when i...
For a Schlage "C" keyway:
Specify "CP6" as the cylinder suffix when ordering D100 or D200 locks (All other Schlage keyways are not available).
Schlage changed to the Everest 29 default keyway on March 4th, 2013. At that time, Everest 29 S123 became the default keyway for all Schlage locks. Everest product is still available but must be sp...
The Schlage B and BD cylinder suffixes designate less small format interchangeable core (SFIC) cylinder prep for the lock. Any SFIC, 6-pin or 7-pin, can be inserted into the lock and will operate t...
Medeco does offer a key-in-lever cylinder to fit the Schlage ND.
You will need to contact Medeco for the cylinder
Specify a key-in-lever cylinder to fit the Schlage ND lo...
The Schlage L-Series uses a clover leaf cam with the exception of the L9060 outside cylinder which uses a straight cam. The cam part number will depend on the type of mortise cylinder, keyway (for ...