This application is not recommended as elelctric strikes have never been tested with XP98/99 exit device because it would defeat the XP device holding force purpose. The holding force f...
This is not a recommended application as the electric strike does not have the same holding force as the XP98/99 rim exit device. The electric strike has 1500 pounds of holding force whereas the ...
The Von Duprin XP98/99 device uses a different strike than standard 98/99 device.
The 909 strike is for non fire rated XP devices and the 954 strike is for the fire rated XP device.
49/9954 mul...
Von Duprin does not recommend using XP98/99 devices with any electric strike.
Von Duprin recommends using the standard 98/99 rim device. The XP device has 2000 pound holding forc...
The latch bolt on an XP98/99 exit device does not retract. The latch bolt will release and pivot out of the way when push bar is depressed or out side trim is activated.
The hole should be drilled in the field once the end cap is located on the door. It is a 5/8" hole, that is located 5/16" from the end of the mechanism case. See installation instruction of t...
There are two main differences:The bottom latches are differentThe Von Duprin 98/9947 concealed vertical rod device covers up to 1/4" undercutThe Von Duprin 98/9948 concealed vertical rod device co...
This is possible: For metal doors prep door according to the 24R/V NL-OP Template or the 25R/V NL-OP Template and for wood doors use 24R/V NL-OP Wood Template or 25R/V...
See the attached Technical Note for instructions on saving a "Device Template" FROM a device or loading TO a device, Device Template Tech NoteOn the SUS/HHD go to the LOCK Properties tab, and sele...
Click Here to view the Hollow Metal or Wood Door Templates for Von Duprin devices
The E996L trim and RX98/99 devices use the standard 996L and 98/99 templa...
If a door is being held open by the LCN SEM 7800/1900 magnet or any ME/SE Series Sentronic LCN closer, you can remotely release that door to close by ordering the following parts and wi...
The Fusible Link arm is available with the 4010, 4020 and 4110 series closers. They all use the same Fusible Link arm. The UL Listing number is for the Fusible Link arms is R1943.
The 4010 Serie...
There is not a wood template for 9957 three point latches, use the 98/99 rim template W10301 to get the correct device backset. For NL trim (990NL) use trim template and installation instruction W...
The NL-OP function for 25-C uses the 718C trim, so template T-2211 for metal doors and W-2211 for wood doors for 718 trims prior to 2/28/2011.
T-2211 for trims prior to 2/28/2011
W-2211 for...