xp electric strike

RELATED FAQS

Question
Answer
Von Duprin does not recommend using XP98/99 devices with any electric strike.   Von Duprin recommends using the standard 98/99 rim device.   
This is not a recommended application as the electric strike does not have the same holding force as the XP98/99 rim exit device. Typically the XP device will withstand a higher force than electr...
The 909 strike is used in single and paired non-fire rated and single fire rated openings.  The 954 strike is used in fire rated paired openings.
The 1609 strike cannot be used with Von Duprin XP98/99 exit device.
This application is not recommended as elelctric strikes have never been tested with XP98/99 exit device because it would defeat the XP device holding force purpose.  
The Von Duprin XP98/99 device uses a different strike than standard 98/99 device. The 909 strike is for non fire rated XP devices and the 954 strike is for the fire rated XP device. 49/9954 mul...
The latch bolt on an XP98/99 exit device does not retract. The latch bolt will release and pivot out of the way when push bar is depressed or out side trim is activated.